Standard :
- DIN VDE 0815
- Zero halogen, non-corrosive gases: IEC 60754-2, DIN EN 50267
- Flame retardant:IEC 60332-1-2, DIN EN 60332-1-2
- Fire retardant:IEC 60332-3-24, DIN EN 60332-3-24
- Smoke density: IEC 61034, DIN EN 61034(LSZH)
Schematic:

Construction :
- Conductor Material: Solid Copper
- Conductor diameter (mm): 0.32 / 0.40 / 0.50 / 0.60 / 0.70 / 0.80 / 0.90
- Insulation Material: PVC
- Insulation Material: LSZH / PVC
- Lapping: Plastic foil
- Shield: Tinned drain wire; plastic-laminated aluminium foil
- Armouring: Dual-sided plastic-coated aluminum tape
- Outer sheath: PE/PVC-FR; Termite protected; Colour: black RAL 9005
| Dimension | Sheath thickness | Diameter | Cable weight | Copper index |
| mm | mm | kg/km | kg/km | |
| 2×2×0.8 | 1.8 | 11.0 | 180 | 25 |
| 4×2×0.8 | 1.8 | 12.5 | 235 | 45 |
| 8×2×0.8 | 1.8 | 15.5 | 340 | 85 |
| 12×2×0.8 | 1.8 | 16.0 | 410 | 126 |
| 16×2×0.8 | 1.8 | 17.0 | 480 | 166 |
| 20×2×0.8 | 1.8 | 19.0 | 560 | 206 |
| 32×2×0.8 | 2.0 | 24.0 | 850 | 327 |
| 40×2×0.8 | 2.0 | 26.0 | 960 | 407 |
| … |
This specification is available for up to 2400 pairs*.
Electrical Properties:
- (Conductor) loop resistance max. :73.2 Ω/km
- Insulation resistance min. :100 MΩ x km
- Test voltage core-core:500 V 50 Hz 1 min
- Test voltage core-screen: 2000 V 50 Hz 1 min
- Peak operating voltage:225 V
- Temperature range moved:-5°C to +50°C
- Temperature range static:-30°C to +70°C
- Minimum bending radius: 7.5 x diameter